• 产品描述

    MATERIAL PROPERTIES

    Color:

    Off-white

    Composition:

    PTFE with barium sulfate

    Fluid Service (see chemical resistance guide):

    Strong caustics, moderate acids, chlorine, gases, water, steam,

    cryogenics, hydrocarbons and aluminum fluoride

    Temperature

     

    Minimum:

    -450°F (-268°C)

    Ideal Operating Limit:

    400°F (204°C)

    Maximum:

    500°F (260°C) see chart→

    Pressure

     

    Ideal Operating Limit:

    750 psig (52 bar)

    Maximum:

    1200 psig (83 bar) see chart→

    Bacterial Growth:

    Will Not Support

    Specifications:

    FDA, USP <87> <88> <661>, TA Luft Approved, REACH / RoHS Compliant

     

    TYPICAL PHYSICAL PROPERTIES

    ASTM F36L

    Compressibility (average):

    43%

    ASTM F36L

    Recovery:

    18%

    ASTM D1708

    Tensile (across grain):

    2,000 psi (13.8 MPa)

    DIN 52913

    Load Retention

     

     

    16 hrs @ 500°F (260°)  7,250 psi (50MPa) gasket stress

    50%


    DESIGN & PERFORMANCE VALUES

    ASTM F3149

    Design Factors

     

     

    “m” factor:

    2.5

     

    “y” factor:

    2,000 psi (13.8 MPa)

    ASTM ROTT

    Gasket Constants

     

     

    Gb:

    248 psi

     

    a:

    0.368

     

    Gs:

    0.939 psi

    ASTM HOBT2

    Hot Blowout with thermal cycles

     

     

    Rating at 435 psig:

    475°F (246°C)


    SEALING CHARACTERISTICS

    ASTM F37B

    Sealability (0.2” ID x 1.20” OD test gasket size)

     

     

    Fuel A – 9.8 psig, 1,000 psi gasket stress:

    0.2 ml/hr

     

    Nitrogen – 30 psig, 3,000 psi gasket stress:

    0.2 ml/hr

    DIN 3535

    Gas Permeability

     

     

    Part 6 – 580 psig (40 bar), 4,640 psi (32 MPa) gasket stress:

    0.0005 mg/m*s

     

    Part 4 – 580 psig (40 bar), 4,640 psi (32 MPa) gasket stress:

    <0.006 cc/min


    EN 13555 CHARACTERISTICS

     

    Test

    Method

    units

    GYLON® EPIX Style 3510 EPX

    Maximum Tolerated Assembly Stress

    (Qsmax)

    In accordance to DIN EN 13555

    68°F (20°C)

    EN 13555

    psi (MPa)

    33,350 (230)

    212°F (100°C)

    EN 13555

    psi (MPa)

    23,200 (160)

    302°F (150°C)

    EN 13555

    psi (MPa)

    20,300 (140)

    392°F (200°C)

    EN 13555

    psi (MPa)

    17,400 (120)

    482°F (250°C)

    EN 13555

    psi (MPa)

    14,500 (100)

     

    Minimum Stress (Qmin)

    needed to reach 0.01 [mg/(s*m)]

    150-600 psig (10-40 bar)

    EN 13555

    psi (MPa)

    725 (5)

    1,160 psig (80 bar)          

    EN 13555

    psi (MPa)      

    1,450 (10)        

    Maximum Sealability Class at 68°F

    (20°C) at 2,900 psi (20 MPa) Assembly

    stress

    145-290 psig (10-20 bar)

    EN 13555

    L[mg/(s*m)]

    1.0x10-4

    580-1,160 psig (40-80 bar)

    EN 13555

    L[mg/(s*m)]

    1.0x10-3

    Maximum Sealability Class at 68°F

    (20°C) at 23,200 psi (160 Mpa)

    assembly stress

     

    580 psig (40 bar)

     

    EN 13555

     

    L[mg/(s*m)]

    1.0x10-5

     

    Initial & Residual Assembly Stress required to achieve sealability of 0.01 [mg/(s*m)]

    (In accordance with DIN EN 13555 test method)

    Corresponding  Pressure

    Initial Assembly Stress

    (QA)

    Residual Assembly Stress

    150 psig (10 bar)

    1,450 psi (10 Mpa)

    435 psi (3 MPa)

    300 psig (20 bar)

    1,450 psi (10 Mpa)

    725 psi (5 MPa)

    600 psig (40 bar)

    1,450 psi (10 Mpa)

    725 psi (5 MPa)

    1,160 psig (80 bar)

    2,900 psi (20 Mpa)

    1,450 psi (10 MPa)

     

    Data in accordance to DIN EN 13555 for calculations to be done in accordance to DIN EN 1591-1 
    Data can be used for ASME PCC-1:2013 including Appendix “I” or Appendix “O”. 
    Please contact Garlock Engineering if gasket cross-section (width) is less than 0.5” (12.7mm).

     

    LEGEND: 
    1 - Suitable for use if chemically compatible and installed using Garlock’s recommended installation practices and assembly stresses. 
    2 - Please consult Garlock Applications Engineering to confirm the suitability with your service conditions. 
    3 - Generally not suitable – please consult Garlock Applications Engineering to confirm the suitability with your service conditions.

相关产品


获取免费报价

我们的代表将很快与您联系。

提交