• 产品描述

    MATERIAL PROPERTIES

    Color:

    Fawn

    Composition:

    PTFE with silica
    Fluid Services (see chemical resistance guide): Strong acids (except hydrofluoric), steam, solvents, hydrocarbons, chlorine and cryogenics

    Temperature2 , °F (°C)

    Minimum:

    -450 (-268)

    Minimum:

    +500 (+260)

    Pressure2 , Maximum, psig (bar):

    1200 (83)

    P x T (max.)2 , psig x °F (bar x °C)

    1/32 and 1/16":

    350,000 (12,000)

    1/8":

    250,000 (8,600)

    Flammability:

    Will Not Support Flame

    Bacterial Growth:

    Will Not Support

    Meets Specification:

    ABS (American Bureau of Shipping), FDA (Food and Drug Administration) and USDA (US Department of Agriculture)

     

    TYPICAL PHYSICAL PROPERTIES*

    ASTM F36 Compressibility, average, %: 7-12
    ASTM F36 Recovery, %: 40
    ASTM F38 Creep Relaxation, %: 18
    ASTM D1708 Tensile, Across Grain, psi (N/mm2): 2000 (13.8)
    ASTM D792 Specific Gravity: 2.10
    ASTM D1708 Modulus @ 100% Elongation, psi (N/mm2): 1600 (11.0)
    ASTM F433 Thermal Conductivity (K), W/m°K (Btu.·in./hr.·ft.2·°F): 0.36-0.45 (2.50-3.15)
    ASTM D149 Dielectric Properties, range, volts/mil.  
      Sample conditioning 1/16" 1/8"
      3 hours at 250°F: 362 -
      96 hours at 100% Relative Humidity 61 -
    ASTM F586 Design Factors 1/16" & Under 1/8"
      "m" factor: 5.0 5
      "y" factor, psi (N/mm2): 2750 (19.0) 3500 (24.1)
    ROTT Gasket Constants:      
      1/16": Gb=940 a=0.253 Gs=2.6
      1/8": Gb=1980 a=0.169 Gs=0.393


    SEALING CHARACTERISTICS

    Gasket Load, psi (N/mm2):

    ASTM F37B – Fuel A DIN 3535 – Nitrogen

    1000  (7)

    4640  (32)

    Internal Pressure, psig (bar)

    9.8  (0.7)

    580  (40)

    Leakage

    0.12 ml/hr.

    <0.015 cc/min

     

    Notes:
    * This is a general guide and should not be the sole means of selecting or rejecting this material. ASTM test results in accordance with ASTM F-104; properties 
    1.Based on ANSI RF flanges at our preferred torque. When approaching maximum pressure, continuous operating temperature, minimum temperature or 50% of  maximum PxT, consult Garlock Applications Engineering. Minimum temperature rating is conservative.